  • 摘要: 本文说明了测定传热系数对连铸的重要性,给出了计算传热系数的方法。所研制的传热系数测定仪包括加热控温系统、温度信号放大与采集系统、数字计算与打印系统等。测定仪装有8位单板计算机和24行微型点阵式打印机。从加热温度传感器到打印测定结果,整个测试过程可连续自动进行。在同样条件下的测定结果稳定可靠。

     

    Abstract: This paper analyzes the importance of measuring heat tranfer coefficient in continuous casting in theory and sets out the way to calculate heat transfer coefficient and to design the apparatus. It consists of heating and controlling temperature system. It can amplify and collect the signal system, calcaulate and type the results of system, etc. There is a 8 bit micro-computer and micro-typcr in it.The process,from heating the probe to typing the result, can be done automatically. The measurement was made for many times in same conditions and the results were stable and reliable.

     

/