“交叉热线”测量固体材料的热导率:测温热电偶的影响

Thermal Conductivity Measurement of Materials by Cross Hot-wire Method: the Effect of Thermal Couple on the Measure

  • 摘要: 对"交叉热线"实验中测温热电偶尺寸对材料热导率测量精度的影响做出了理论分析,推导出一个实用的热线温升修正关系式。用它对硅藻土砖、轻质粘土砖和建筑红砖这类不透明固体的热导率进行了测试,结果与平面热源法及文献中的数据相符合,此外,在300~1300K温度范围内,对K9冕玻璃试样的热导率进行了测量。

     

    Abstract: The effect of thermal couple on the thermal conductivity measurement by cross hot-wire method was theoretically analyzed, a practical correction formula for the temperature rise of wire was presented. The thermal conductivity of nontransparent solid materials such as diatomaceous brick, light clay brick and building brick were measured, and the experimental results conform with the data of heat-plane method and some references. Moreover, the thermal conductivity of one especial glass sample-glass K9 is reported in the temperature range 300~1300 K.

     

/

返回文章
返回