  • 摘要: 在常温下,采用固体颗粒层进行过滤除尘的实验研究,并对实验结果进行分析,探索了过滤介质粒径、过滤层厚度和过滤速度对除尘效率和床层压力差的影响.根据实验结果,确定了最佳的过滤介质粒径、过滤层厚度和过滤速度.

     

    Abstract: Based on the experiment of dust removal in a granular layer at normal temperature and the analysis of the Based on the experiment of dust removal in a granular layer at normal temperature and the experimental results, the influence of filter particle diameter, layer thickness and filtration velocity on the dust removal efficiency was researched. The result gave the optimal filter particle diameter, layer thickness and filtration velocity.

     

/