Tong Chaonan, Sun Yikang, Xu Guang, Yang Jie, Fang Jun, Wang Chengji. The Application of Adoptive Control to the Tension-AGC System on Cold Tandem Mill[J]. Chinese Journal of Engineering, 1989, 11(1): 52-56. DOI: 10.13374/j.issn1001-053x.1989.01.010
Citation: Tong Chaonan, Sun Yikang, Xu Guang, Yang Jie, Fang Jun, Wang Chengji. The Application of Adoptive Control to the Tension-AGC System on Cold Tandem Mill[J]. Chinese Journal of Engineering, 1989, 11(1): 52-56. DOI: 10.13374/j.issn1001-053x.1989.01.010

The Application of Adoptive Control to the Tension-AGC System on Cold Tandem Mill

  • The analysis of tension AGC system in the tandem cold mill shows that it is a time-varing dynamic system, so that the minimum variance self-tuning regulator is used. After the system is identified and simulated, the results how that the control effect of self-tuning regulator is better than that of PID regulator and the recursive least square with forgetting factor is a better identification algorithm. The application of self-tuning regulator in an actual tention AGC system shows that the gauge deviations of the controlled strip are greatly decreased.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return