A New Electrochemical Sensor for Rapid Determination of Silicon Content in Carbon Saturated Iron
-
-
Abstract
Laboratory EMF measurements were conducted in Fe+C(sat)+Si system using ZrO2 (MgO) solid electrolyte equipped with a new auxiliary electrode SiO2+CaF2. The results showed that the measured EMFs reaches stable value within 5 seconds after immersion of the developed silicon probe into the above melt; the relation between measured EMFs and silicon activity corresponds with the theoretical calculation; the measured EMFs were nearly independent of measured temperature from 1 694 to 1 749K. Due to the rapid response and accuracy of the silicon probe developed in this study, it is expected to be used in situ.
-
-