Inherent Contradictory of Hot Strip Rolling AGC System
Analyzes two basic control modes of hot strip mill AGC system:GM mode and X-ray monitor mode, uncovers the conflict between GM and X-ray monitor modes and its harmful effects for thickness error elimination, and gives the new concept of AGC weak control area and its basic characteristics.